5.2 “飓风” 旋转喷雾雾炮(新) Hurricane-Rotary Misting Cannon (New)

HF35D喷嘴喷雾系统改造成 “飓风”旋转喷雾系统 HF35D nozzle misting system has been reformed into Hurricane rotary misting system

“飓风”旋转喷雾雾炮是专门设计用来控制灰尘和气味。它取代了传统的由喷嘴和高压泵系统组成的高压喷嘴喷雾系统,从而消除了喷嘴堵塞的高维护率的麻烦,和高压泵不宜长时间连续工作和故障频发的致命缺点。由于消除压泵,所以也大大减少了用电量。这是一个独立可移动式机组,拖动灵活,操作方便,只要接上自来水管或低压水泵供水,接上电源就可以工作。

由HF35D喷嘴喷雾系统改造成 “飓风”旋转喷雾系统,经历了四个步骤 Finishing the new technology developement, it had been subject to four steps:

1.完成由“旋转喷雾”系统代替“高压喷嘴”系统的改装; Replaced the high pressure nozzle system witth rotary misting system;

2.完成管路系统的装配: 与原有的喷嘴系统相比,此系统卸掉了所有的高压系统部件,如高压泵及电机,及高压管路包括喷嘴;取而代之的是用一个低压离心泵来给雾头供水, 出水“过滤器”从原来喷嘴系统的水箱口的位置移到了离心泵的出水端(正压) 一边,这样的好处是: 离心泵从水箱吸水时不会受过滤器的影响; have pipe system to be set up: As compared with nozzle system, this system needs to removal of electric motor for high pressure pump and the high pressure pump, as well as the high pressure pipes including nozzles; Instead, a centrifuge pump will be used for supplying water to the misting head; The filter is eliminated at this point but reinstalled on the outflow side of the pump and behind Rotary head water supply valve and before the rotary misting head so that there is no interference with the pump sucking water from the main tank;

3.管路线路和雾头的连接大大简化:入水通过一个药箱配比泵后,直接接到雾头。

4.VFD和PLC控制程序修改: VFD 是用来控制电机转速,使之快速均匀,提高系统的效率。它还可用来编程控制电机。

 

更多的照片,请点击此处 Click here for more pictures